Simple Extractive Spectrophotometric Method for Determination of Candesartan Cilexetil by Reactive Dyes from Pharmaceutical Dosage Form

 

Rajan V. Rele, Prathamesh P. Tiwatane

Central Research Laboratory, D.G. Ruparel College, Matunga, Mumbai 400016.

*Corresponding Author E-mail: drvinraj@gmail.com

 

ABSTRACT:

Simple sensitive and accurate extractive spectrophotometric methods have developed for the estimation of Candesartan cilexetil pharmaceutical dosage form. The methods are based on the formation of coloured complexes by the drug with reagents like congo red, methyl orange and eriochrome black T in acidic medium. The ion associated complexes were formed and quantitatively extracted under the experimental condition in chloroform. The absorbance values were measured at 490nm, 430nm and 500nm respectively. The proposed methods were validated statistically. Recoveries of methods were carried out by standard addition methods. The linearity was found to be 4.0-24.0.0μg/ml, 2 -18μg/ml, 2-14μg/ ml for methods 1, 2 and 3 respectively. The low values of standard deviation and percentage RSD indicate high precision of methods. Hence these methods are useful for routine estimation of Candesartan cilexetil in tablets.

 

KEYWORDS: Candesartan cilexetil, Methyl orange, Congo, Red, Eriochrome black T, Chloroform.

 

 


INTRODUCTION:

Candesartan is an antihypertensive drug commercially available as cilexetil (cyclohexyl 1-hydroxy ethyl carbonate) ester form. It is a pro-drug and is hydrolyzed to candesartan during absorption from the gastrointestinal tract. Candesartan is a selective AT1 subtype angiotensin II receptor antagonist. It is a non-peptide, chemically described as (±)-1-Hydroxyethyl 2-ethoxy-1- [p-(o-1H-tetrazol-5-ylphenyl) benzyl]-7-benzimidazolecarboxylate, cyclohexyl carbonate (ester) Candesartan cilexetil is white to off-white crystalline powder with a molecular weight of 610.67. It is practically insoluble in water and soluble in methanol. Candesartan cilexetil is a racemic mixture containing one chiral center at the cyclohexyloxycarbonyl-oxy ethyl ester group.

 

Following oral administration, Candesartan cilexetil undergoes hydrolysis at the ester link to form the active drug, candesartan. Literature survey reveals the Spectrophotometric1-6, HPLC7-13, UPLC14 and non-aqueous titration15 methods for the estimation of candesartan cilexetil. Simple, rapid and reliable UV spectrophotometric methods are developed for the determination of candesartan cilexetil. These methods can be used for the routine analysis. In the proposed methods optimization and validation of this method are reported.

 

Structure of candesartan cilexetil

 

 

MATERIALS AND METHOD:

Instrument and Reagents:

Spectral scan was made on a Shimadzu UV-spectrophotometer, model 1800 (Shimadzu, Japan) with spectral band width of 0.5 nm with automatic wavelength corrections by using a pair of 10 mm quartz cells.

 

Reference standard of Candesartan cilexetil was obtained from reputed firm with certificate of analysis.

 

Preparation of Standard Drug Solutions:

Stock solution of Candesartan cilexetil (100μg/ml) was prepared in ethanol. From this stock solution working standard (10μg/ml) was prepared by diluting 10ml stock solution to 100ml with distilled water. 0.6% w/v solution of bromophenol blue, 0.25% w/v solochrome dark blue and 0.2% w/v bromocresol green were prepared in distilled water respectively.

 

Potassium hydrogen phthalate buffer solution of pH 4.01was prepared in distilled water. Dilute hydrochloric acid was used to adjust desired pH of buffer solution.

 

Preparation of Reagent:

A 0.05 % w/v Congo red, 0.25% eriochrome black T and 0.02% methyl orange solutions were prepared in distilled water respectively.

 

Potassium hydrogen phthalate buffer solution of pH 4.01was prepared in distilled water. Dilute hydrochloric acid was used to adjust desired pH of buffer solution.

 

Estimation from Tablets:

Twenty tablets were weighed accurately and average weight of each tablet was determined. Powder equivalent to 10mg of Candesartan cilexetil was weighed and transferred in 100ml of volumetric flask. A 30ml of ethanol was added and sonicated for 15 minutes and filtered. The filtrate and washing were diluted up to the mark with distilled water to give concentration as 100μg /ml. Such solution was used for analysis.

 

EXPERIMENTAL:

Method 1(with Congo red):

Into a series of separating funnels appropriate amount of the working standard drug solutions were pipetted out. To each funnel 1.2ml of buffer (pH= 3.9) and 4.1ml of 0.05 %w/v Congo red were added. 10 ml of chloroform was added to each funnel. The solutions were shaken for thorough mixing of the two phases and were allowed to stand for clear separation of the layers. The absorbance values of the chloroform layers were measured against their respective reagent blank at the wavelength of the maximum absorbance (λ max 420nm).

 

Method 2(with methyl orange):

Into a series of separating funnels appropriate amount of the working standard drug solutions were pipetted out. To each funnel 2.2ml of buffer (pH = 3.8) and 3.0ml of 0.2% w/v methyl orange were added. 10ml of chloroform was added to each funnel. The solutions were shaken for thorough mixing of the two phases and were allowed to stand for clear separation of the layers. The absorbance values of the chloroform layers were measured against their respective reagent blank at the wavelength of the maximum absorbance (λ max=430 nm).

 

Method 3(with eriochrome black T):

Into a series of separating funnels appropriate amount of the working standard drug solutions were pipetted out. To each funnel 2.0ml of buffer (pH= 3.5) and 4.0ml of 0.025% w/v eriochrome black T were added. 10ml of chloroform was added to each funnel. The solutions were shaken for thorough mixing of the two phases and were allowed to stand for clear separation of the layers. The absorbance values of the chloroform layers were measured against their respective reagent blank at the wavelength of the maximum absorbance (λ max =500 nm).

 

Results of analysis are given in table 1.

Table 1: Values of results of optical and regression of drug

Parameter

Congo red

Methyl orange

Eriochrome black T

Detection Wavelength (nm)

490

430

500

Beer Law Limits (µg/ml)

4-24

2-18

2-14

Correlation coefficient(r2)

0.9996

0.9999

0.9993

Regression equation (y=b+ac)

 

 

 

Slope (a)

0.0201

0.0199

0.015

Intercept (b)

0.0019

0.0012

0.0045

 

RESULTS:

The extractive spectrophotometric methods are popular due to their sensitivity in assay of the drug and hence ion pair extractive spectrophotometric methods have gain considerable attention for quantitative determination of many pharmaceutical preparations. These proposed methods are extractive spectrophotometric methods for the determination of drug by using chloroform as solvent from its formulations i.e. tablets. The colour ion pair complexes formed are very stable. The working conditions of these methods were established by varying one parameter at time and keeping the other parameters fixed by observing the effect produced on the absorbance of the colour species. The various parameters involved for maximum colour development for these methods were optimized. The proposed methods were validated statistically and by recovery studies. The molar absorptivity show the sensitivity of methods while the precision was confirmed by %RSD (relative standard deviation). The optical characteristics such as absorption maxima (nm), co-relation coefficient (r) were calculated and are also summarized. Assay results of recovery studies are given in table 2 (A,B,C).


 

Table 2: A (Congo red)

Amount of Sample Added in (µg/ml)

Amount of Standard Added in (µg/ml)

Total amount recovered

Percentage recovery (%)

Standard deviation

Percentage of relative standard deviation (C.O.V.)

4

4

4.008561

100.214

0.005557

0.138617

8

8

8.009274

100.1159

0.004493

0.056098

12

12

12.00785

100.0654

0.006978

0.058109

16

16

16.00999

100.0624

0.005766

0.036017

 

 

 

 

Mean=0.005698

Mean=0.07221

 


Table 2: B (Methyl orange)

Amount of Sample Added in (µg/ml)

Amount of Standard Added in (µg/ml)

Total amount recovered

Percentage recovery (%)

Standard deviation

Percentage of relative standard deviation (C.O.V.)

2

0

2.006691

100.3345

0.00578

0.288023

2

2

4.006083

100.1521

0.006237

0.155693

2

4

6.040754

100.6792

0.01782

0.295001

2

6

8.039538

100.4942

0.018473

0.229773

 

 

 

 

Mean=0.012077

Mean=0.242122


 


Table 2: C (Eriochrome black T)

Amount of Sample Added in (µg/ml)

Amount of Standard Added in (µg/ml)

Total amount recovered

Percentage recovery (%)

Standard deviation

Percentage of relative standard deviation (C.O.V.)

2

0

2.011034

100.5517

0.008988

0.446941

2

2

4.021889

100.5472

0.009988

0.24834

2

4

6.016817

100.2803

0.008041

0.133643

2

6

8.015305

100.1913

0.008379

0.104533

 

 

 

 

Mean=0.008849

Mean=0.233364


Results are in good in agreement with labelled value.

 


DISCUSSION:

The percent recovery obtained indicates noninterference from the common excipients used in the formulation. The reproducibility, repeatability and accuracy of these methods were found to be good, which is evidenced by low standard deviation. The proposed methods are simple, sensitive, accurate, precise and reproducible. They are directly applied to drug to form chromogen. Hence they can be successfully applied for the routine estimation of drug, in bulk and pharmaceutical dosage form even at very low concentration and determination of stability of drug in formulation such as tablets. The strong recommendation is made here for the proposed methods for determination of Candesartan cilexetil from its formulation.

 

REFERENCES:

1.      Nawal A. AL-Arfaj, Wedad A. AL-Onazi and Amina M. EL-Brashy, Spectrophotometric Determination of Candesartan Cilexetil in Presence of Its Alkaline Induced Degradation Product. Asian Journal of Chemistry, 23(4); 2011: 1696-1700.

2.      K. K. Pradhan, U. S. Mishra, S. Patnnaik, C. K. Panda, K. C. Sahu, Development and Validation of a Stability-indicating UV Spectroscopic Method for Candesartan in bulk and formulations. Indian Journal of Pharmaceutical Sciences. 73, (6);2011: 693-696.

3.      Anjan Paudel, Ameeduzzafar, Farhan Jalees Ahmad, Mohd Qumbar, Chetan Dhal, Asgar Ali, Stress degradation studies on candesartan cilexetil bulk drug and development of validated method by UV spectrophotometry in marketed tablet. World journal of pharmaceutical science. 3(3); 2014: 3975-3986.

4.      Kalyani G., Vaishnav Y, Deshmukh S.V, Sahu R, Stability Indicating Method Development and Validation of Candesartan in Bulk and Pharmaceutical Dosage Form by Derivative Spectrophotometric Method (First Order). International Journal of Pharmamedix India. 1(2);2013: 222-232.

5.      Rele Rajan V. UV spectrophotometric estimation of candesartan cilexetil by area under curve and second order derivative methods in bulk and pharmaceutical dosage form. Der Pharmacia Lettre, 7 (6);2015:237-243.

6.      Rele Rajan V. Tiwatane Prathmesh P. Determination of Candesartan cilexetil from pharmaceutical dosage form by extractive ion pair complex colorimetric method. Asian J. Research Chem 18(4): 2025;243-245. DOI: 10.52711/0974-4150.2025.00037.

7.      Naga Dileep P.V, Putta Rajesh Kumar, Salahuddin Md., Shanta Kumar S.M, Candesartan cilexetil analytical method development and validation studies by reverse phase HPLC technique. International Journal of Pharmaceutical Frontier Research. 2(3); 2012: 36-43.

8.       R Revathi, T Ethiraj, Jhansi L. Marreddy, V Ganeshan, Development and validation of a dissolution test for Candesartan cilexetil in tablet forms using reverse phase – High performance liquid chromatography Pharm Education Res. 2(2); 2011: 71-77.

9.      V.Kamalakkannan, A. Puratchikody, K. Masilamani, T. Saraswathy, Analytical method development and validation for Candesartan Cilexetil as bulk drug and in pharmaceutical dosage forms by HPLC, Der Pharmacia Lettre. 3(3);2011: 286-296.

10.    Amit Asati, Anita Shinde, Suman Malik, K.C. Asati, Analytical Assay Development and Validation for Estimation of Trityl Candesartan in Bulk Drug by of Reverse Phase Liquid Chromatography Int. J. Pharm. Sci. Rev. Res. 26(1);2014: 169-173.

11.   Syeda Kulsum, G Vidya Sagar, K. Nagalakshmi, R. Snehalatha, Development and validation of RP-HPLC method for estimation of candesartan from tablet dosage form. World of pharmacy and pharmaceutical science. 3(4); 2014:781-786.

12.   Manisha P Puranik, Sailesh J Wadher, Ashish L Kosarkar, Pramod G Yeole, Method Development and Validation of Candesartan cilexetil by RP-HPLC International Journal of Research in Pharmaceutical and Biomedical Sciences, 3(3);2014: 1227-1230.

13.    Manju Latha Y.B. Gowri ShankarD. stability indicating RP-HPLC method for determination of candesertan in pure and pharmaceutical formulation. International journal of pharmacy and industrial research, 1(4);2011: 344-349.

14.   Gunda Srinivas, Kakumani Kishore Kumar, Gangaram V. Kanumula, M. Vishnu Priya1, K. Mukkanti , A Stability Indicating UPLC Method for Candesartan in Bulk Drug Samples American Journal of Analytical Chemistry. 3; 2012: 704-709.

15.   Rele Rajan V. A validated non-aqueous potentiometric titration method for quantitative determination of candesartan cilexetil from pharmaceutical preparation. Int. J. Chem. Sci. 14(4); 2016: 2696-2702.

 

 

 

 

Received on 04.09.2025      Revised on 19.09.2025

Accepted on 27.09.2025      Published on 30.09.2025

Available online from October 07, 2025

Asian J. Research Chem.2025; 18(5):345-347.

DOI: 10.52711/0974-4150.2025.00053

©A and V Publications All Right Reserved

 

This work is licensed under a Creative Commons Attribution-Non Commercial-Share Alike 4.0 International License. Creative Commons License.